NO: The thermistor control mechanism is faulty. Is the drive voltage of the heater supplied by the connector J8 of the main power supply PCB? Main heater: between J8-1 (FSR1) and J8-5 (FSR COM) Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM) YES: The heater drive power supply is faulty. Canon iR3320 Code: E000-0000 Description: The reading of the main thermistor does not reach 30C 1 sec after the main power switch is turned on. Main power supply PCB, DC controller PCB Press the Start key. Is it W (open)? YES: The heater has an open circuit, or the thermal switch is open. Fixing film unit (thermistor) Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of the connectosr (4-pin) of the thermistor for electrical continuity. DC controller PCB (J320) relay connector thermistor NO: Connect the connector. main power supply PCB (J8) relay connector heater b. ![]() Connector Is the connector of the fixing assembly connected? a. To reset the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
|